FP-260 Special fluor polymer high temperature PTFE heat-shrinkable tube

Special fluor polymer high temperature flame retardant hydrophobic heat-shrinkable tube with peculiar chemical resistance made by extrusion from polytetrafluorethylene (fluoroplastic-4, PTFE).

 

Application: Special fluor polymer heat shrinkable tubes from PTFE are used in conditions of simultaneous effect of aggressive environment and extremely high temperatures providing mechanical and electrical protection of different electromechanical parts, indicators and components in condition of contact with aggressive chemical substances and big temperature differences. Has low coefficient of sliding fracture. Tubes are recommended to use in medical, chemical, oil and gas industry, aerospace, military, automotive, mining and other fields of industry with high fire and chemical resistance requirements.

Storage: in clean, dry rooms in the supplier's packaging or in cardboard boxes, at relative humidity of up to 70%, at temperatures from -10°C to +50°C, avoiding sudden temperature changes and exposure to direct sunlight. The distance to any heating sources should be at least 1 meter (without exceeding the maximum storage temperature). Storage conditions should exclude the influence of aggressive medium: acids, alkalis, fuels and lubricants, solvents, etc.

Packing specification:  Tube is supplied in pieces of 1,22m/pc, packed in cartoon tubes, boxes, in packaging film.

Certification: Not subject to mandatory certification

Basic technical specifications:

Operating temperature

from -65°С to +260°С (up to -190°С without mechanical load, in calm)

Shrink temperature

+350°С +/-10°С (this temperature should be on the surface of the tube for a full shrink)

Heat Shrink Ratio

1,7:1; 2:1; 4:1 (depending on product type)

Flammability

Doesn't burn in open flame, slowly destroys with extraction of toxic substances, OI > 95

Standart color

Transparent with bluish hint

Size range:

ID from 0,5 to 57mm

Longitudinal shrinkage:

Up to +/- 20% (with consideration high coefficient of heat extension / shrinking)

Technical details:


Test item

Test Method

Result

Breakdown strength, МPа

ASTM D638

20-35

Relative breakdown elongation, %

ASTM D638

200-550

Dencity, g/cm3

ASTM D792

≥ 2,1

Shore hardness, method D

ASTM D2244

≥ 50

Dielectric strength, kV/mm

ASTM D149

up to 24

Radiation resistance, megarad

-

1 (10 kJ/kg)

Dielectric constant 1MHz

ASTM D150

2,1

Volume resistivity, Ω·cm

ASTM D257

≥ 1 х 1014

Table 1. Size range of heat shrinkable tubes with shrink ratio 1,7 : 1


Size, mm

Sizes before shrink with tolerance

Sizes after full shrink

ID, mm

WT, mm

ID, mm

WT, mm

Ø 0,5

0,5 +/- 0,20

0,10 +/- 0,05

≤ 0,40

0,15 +/- 0,05

Ø 0,8

0,8 +/- 0,20

0,10 +/- 0,05

≤ 0,48

0,15 +/- 0,05

Ø 1,0

1,0 +/- 0,20

0,10 +/- 0,05

≤ 0,66

0,15 +/- 0,05

Ø 1,3

1,3 +/- 0,20

0,10 +/- 0,05

≤ 0,80

0,20 +/- 0,05

Ø 1,5

1,5 +/- 0,20

0,10 +/- 0,05

≤ 0,97

0,20 +/- 0,05

Ø 2,0

2,0 +/- 0,20

0,10 +/- 0,05

≤ 1,32

0,20 +/- 0,05

Ø 2,5

2,5 +/- 0,30

0,10 +/- 0,05

≤ 1,65

0,20 +/- 0,05

Ø 3,0

3,0 +/- 0,30

0,15 +/- 0,05

≤ 1,83

0,20 +/- 0,05

Ø 3,5

3,5 +/- 0,30

0,15 +/- 0,05

≤ 2,05

0,20 +/- 0,05

Ø 3,8

3,5 +/- 0,30

0,15 +/- 0,05

≤ 2,31

0,20 +/- 0,05

Ø 4,0

4,0 +/- 0,30

0,15 +/- 0,05

≤ 2,31

0,20 +/- 0,05

Ø 4,5

4,5 +/- 0,30

0,15 +/- 0,05

≤ 2,57

0,20 +/- 0,05

Ø 5,0

5,0 +/- 0,30

0,15 +/- 0,05

≤ 3,10

0,20 +/- 0,05

Ø 6,0

6,0 +0,5 / -0,20

0,15 +/- 0,05

≤ 3,80

0,25 +/- 0,05

Ø 7,0

7,0 +0,5 / -0,20

0,18 +/- 0,05

≤ 4,20

0,25 +/- 0,05

Ø 8,0

8,0 +0,5 / -0,20

0,18 +/- 0,05

≤ 4,80

0,25 +/- 0,05

Ø 9,0

9,0 +0,7 / -0,20

0,18 +/- 0,05

≤ 5,30

0,25 +/- 0,05

Ø 10,0

10,0 +0,7 / -0,20

0,20 +/- 0,05

≤ 6,20

0,25 +/- 0,05

Ø 11,0

11,0 +0,7 / -0,20

0,20 +/- 0,05

≤ 6,30

0,25 +/- 0,05

Ø 12,0

12,0 +0,7 / -0,20

0,20 +/- 0,05

≤ 6,95

0,25 +/- 0,05

Ø 13,0

13,0 +0,7 / -0,20

0,20 +/- 0,05

≤ 7,1

0,25 +/- 0,05

Ø 14,0

14,0 +0,7 / -0,20

0,20 +/- 0,05

≤ 7,7

0,25 +/- 0,05

Ø 15,0

15,0 +0,7 / -0,20

0,20 +/- 0,05

≤ 8,8

0,25 +/- 0,05

Ø 16,0

16,0 +0,7 / -0,20

0,20 +/- 0,05

≤ 9,4

0,25 +/- 0,05

 

Table 2. Size range of heat shrinkable tubes with shrink ratio 2 : 1


Size, mm

Sizes before shrink with tolerance

Sizes after full shrink

ID, mm

WT, mm (standard wall tube)

WT, mm
(heavy wall tube)

ID, mm

WT, mm (standard wall tube)

WT, mm
(heavy wall tube)

Ø 0,8

0,8 +/- 0,20

0,10 +/- 0,05

0,15 +/- 0,05

≤ 0,40

0,15 +/- 0,05

0,25 +/- 0,05

Ø 1,0

1,0 +/- 0,20

0,10 +/- 0,05

0,15 +/- 0,05

≤ 0,53

0,15 +/- 0,05

0,25 +/- 0,05

Ø 1,5

1,5 +/- 0,20

0,10 +/- 0,05

0,20 +/- 0,05

≤ 0,81

0,15 +/- 0,05

0,30 +/- 0,05

Ø 2,0

2,0 +/- 0,20

0,10 +/- 0,05

0,20 +/- 0,05

≤ 1,07

0,15 +/- 0,05

0,30 +/- 0,05

Ø 2,5

2,5 +/- 0,30

0,10 +/- 0,05

0,20 +/- 0,05

≤ 1,32

0,15 +/- 0,05

0,30 +/- 0,05

Ø 3,0

3,0 +/- 0,30

0,10 +/- 0,05

0,20 +/- 0,05

≤ 1,65

0,15 +/- 0,05

0,30 +/- 0,05

Ø 3,5

3,5 +/- 0,30

0,15 +/- 0,05

0,20 +/- 0,05

≤ 1,83

0,20 +/- 0,05

0,30 +/- 0,05

Ø 4,0

4,0 +/- 0,30

0,15 +/- 0,05

0,20 +/- 0,05

≤ 2,05

0,20 +/- 0,05

0,30 +/- 0,05

Ø 4,5

4,5 +/- 0,30

0,15 +/- 0,05

0,20 +/- 0,05

≤ 2,31

0,20 +/- 0,05

0,30 +/- 0,05

Ø 5,0

5,0 +/- 0,30

0,15 +/- 0,05

0,20 +/- 0,05

≤ 2,57

0,20 +/- 0,05

0,30 +/- 0,05

Ø 6,0

6,0 +0,5 / -0,20

0,15 +/- 0,05

0,25 +/- 0,05

≤ 3,10

0,20 +/- 0,05

0,38 +/- 0,05

Ø 7,0

7,0 +0,5 / -0,20

0,15 +/- 0,05

0,25 +/- 0,05

≤ 3,53

0,20 +/- 0,05

0,38 +/- 0,05

Ø 8,0

8,0 +0,5 / -0,20

0,15 +/- 0,05

0,25 +/- 0,05

≤ 4,00

0,20 +/- 0,05

0,38 +/- 0,05

Ø 9,0

9,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 4,50

0,25 +/- 0,05

0,38 +/- 0,05

Ø 10,0

10,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 5,00

0,25 +/- 0,05

0,38 +/- 0,05

Ø 11,0

11,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 5,53

0,25 +/- 0,05

0,38 +/- 0,05

Ø 12,0

12,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 6,2

0,25 +/- 0,05

0,38 +/- 0,05

Ø 13,0

13,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 6,7

0,25 +/- 0,05

0,38 +/- 0,05

Ø 14,0

14,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 7,2

0,25 +/- 0,05

0,38 +/- 0,05

Ø 15,0

15,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 7,8

0,25 +/- 0,05

0,38 +/- 0,05

Ø 16,0

16,0 +0,8 / -0,20

0,18 +/- 0,05

0,25 +/- 0,05

≤ 8,2

0,25 +/- 0,05

0,38 +/- 0,05

 

Table 3. Size range of heat shrinkable tubes with shrink ratio 4 : 1

Size, mm

Sizes before shrink with tolerance

Sizes after full shrink

ID, mm

ID, mm

WT, mm

Ø 3,0

3,0 +/- 0,20

≤ 0,75

0,30 +/- 0,05

Ø 3,5

3,5 +/- 0,20

≤ 0,87

0,30 +/- 0,05

Ø 4,0

4,0 +/- 0,20

≤ 1,00

0,30 +/- 0,05

Ø 4,5

4,5 +/- 0,20

≤ 1,12

0,30 +/- 0,05

Ø 5,0

5,0 +/- 0,20

≤ 1,25

0,30 +/- 0,05

Ø 5,5

5,5 +/- 0,20

≤ 1,37

0,30 +/- 0,05

Ø 6,0

6,0 +/- 0,30

≤ 1,50

0,30 +/- 0,05

Ø 7,0

7,0 +/- 0,30

≤ 1,75

0,30 +/- 0,05

Ø 8,0

8,0 +/- 0,30

≤ 2,00

0,30 +/- 0,05

Ø 9,5

9,5 +/- 0,30

≤ 2,37

0,30 +/- 0,05

Ø 10,0

10,0 + 0,7 / - 0,20

≤ 2,50

0,20 +/- 0,05

Ø 11,0

11,0 +/- 0,30

≤ 2,70

0,30 +/- 0,05

Ø 12,5

12,5 +/- 0,30

≤ 3,10

0,38 +/- 0,10

Ø 14,0

14,0 +/- 0,30

≤ 3,50

0,38 +/- 0,10

Ø 15,5

15,5 +/- 0,40

≤ 3,80

0,38 +/- 0,10

Ø 17,0

17,0 +/- 0,40

≤ 4,25

0,38 +/- 0,10

Ø 19,0

19,0 +/- 0,40

≤ 4,75

0,38 +/- 0,10

Ø 22,0

22,0 +/- 0,40

≤ 5,50

0,38 +/- 0,10

Ø 25,0

25,0 +/- 0,40

≤ 6,20

0,38 +/- 0,10

Ø 31,5

31,5 +/- 0,40

≤ 7,80

0,38 +/- 0,10

Ø 44,0

44,0 +/- 0,40

≤ 11,00

0,38 +/- 0,10

Ø 50,5

50,5 +/- 0,40

≤ 12,60

0,51 +/- 0,13

Ø 57,0

57,0 +/- 0,40

≤ 14,25

0,51 +/- 0,13