Heat shrinkable isolation tape HSTP

Heat shrinkable isolation tape is made of flame-retardant cross link polyolefins composition. Inner side of the tape has adhesive layer that melts during shrinkage providing sealing of insulating base.

Application: Heat-shrinkable tape HSTP is used for the wide range of applications, primarily for the partial restoration of damaged outer cover of electrical cables in cases of damage occurred as a result of mechanical impact, excessive heat, electrical breakdown, organic solvents and corrosion. The tape can be used for mechanical protection of construction elements subject to mechanical damage, corrosion, abrasion, in high-voltage power engineering for insulation and waterproofing of cables and switches connections, when installing high-voltage cable joints, etc. Under certain conditions the tape can be used for waterproof pipelines. Adhesive layer on the tape provides good sealing of surfaces. 

Usage recommendations: During installation it is recommended to wrap the winding with overlap turn 2/3 of the width of the tape and gradual heating of the turns until the glue appears along the edge of the tape.

Package: in rolls 5m, 10m and 15m long, width 25mm and 50mm, packed in a plastic bag.

Storage: in clean, dry rooms in the supplier's packaging or in cardboard boxes, at a relative humidity of up to 70%, at temperatures from -10°C to +50°C, avoiding sudden temperature changes and exposure to direct sunlight. The distance to any heating sources should be at least 1 meter (without exceeding the maximum storage temperature). Storage conditions should exclude the influence of aggressive medium: acids, alkalis, fuels and lubricants, solvents, etc.

Certification: Not subject to mandatory certification

Parameter

Data

Operational temperatures

from -55 °С to +105 °С

Shrinking temperature

+100о С

Basic color

red, yellow, green, black

 

Additional Technical details:

 

Parameter

Test Method

Result

Tensile strength, МPа

ASTM D2671

≥10,4

Breakdown elongation, %

ASTM D2671

≥ 200

Tensile strength after heat impact, МPа

ASTM D2671 (+120°C х 168h)

≥ 10

Relative elongation after heat impact, %

ASTM D2671 (+120°C х 168h)

≥ 200

Dielectric strength, kV/mm

IEC 60243

≥ 10

Volume resistivity, Ω·cm

IEC 60093

> 1 x 1014

Longitudal shrinkage, %

UL224

≤ 10%

Size

Width (mm)

Thickness (mm)

Standard length (m)

 HSTP-2508

25±2

0.80±0.20

5;10

 HSTP-5008

50±4

0.80±0.20

5;10

 HSTP-10008

100±4

0.80±0.20

5;10

 HSTP-2510

25±4

1.00±0.20

5;10

 HSTP-5010

50±4

1.00±0.20

5;10

 HSTP-10010

100±4

1.00±0.20

5;10